HubWayLD Active Unit - 5 -
1 - White/Orange [VIDEO +]
2 - Orange [VIDEO -- ]
3 - White/Green [DATA +]
4 - Blue [AC 1]
5 - White/Blue [AC 2]
6 - Green [DATA -- ]
7 - White/Brown [AC 2]
8 - Brown [AC 1]
Fig. 3 - CAT-5 Structured Cable Wiring Color Codes and PIN Configurations
Fig. 2
Fig. 2c
Fig. 2a
Fig. 2b Fig. 2d
HubWayAv passes AC voltage from pins 4, 5, 7, 8 to
ter
minals marked [AC Power] (Fig. 3, pg. 5).
HubW
ayDv/HubWayDvi converts AC voltage to DC
voltage from pins 4, 5, 7, 8 to terminals marked
[--12VDC +] (Fig. 3, pg. 5).
HubWayAv, HubWayDv and HubWayDvi Video Balun/Combiners:
HubWayAv
*24VAC/28VAC *24VAC/28VAC
24VAC cameras
Green
HubWayDv
*24VAC/28VAC 12VDC
12VDC cameras
Red
HubWayDvi
*24VAC/28VAC 12VDC electronically isolated 12VDC cameras without isolation Red
Altronix
Model
Number
Output Voltage
to camera
Input Voltage
from HubWay
unit
Camera Type
Power LED
*Based on camera load and structured cable length.